table of contents
NUTSCAN_SCAN_EATON_S(3) | NUT Manual | NUTSCAN_SCAN_EATON_S(3) |
NAME¶
nutscan_scan_eaton_serial - Scan serial ports for Eaton devices (XCP, SHUT and Q1).
SYNOPSIS¶
#include <nut-scan.h>
nutscan_device_t * nutscan_scan_eaton_serial(const char* ports_list);
DESCRIPTION¶
The nutscan_scan_eaton_serial() function tries to detect NUT devices which are compatible with Eaton’s serial device protocols (SHUT, XCP and Q1 (aka blazer)). ports_list is a NULL terminated array of pointers to strings containing serial device name (/dev/ttyS0, COM1, /dev/ttya...)
You MUST call nutscan_init(3) before using this function.
RETURN VALUE¶
The nutscan_scan_eaton_serial() function returns a pointer to a nutscan_device_t structure containing all found devices or NULL if an error occurs or no device is found.
SEE ALSO¶
nutscan_init(3), nutscan_scan_usb(3), nutscan_scan_xml_http(3), nutscan_scan_snmp(3), nutscan_scan_avahi(3), nutscan_scan_ipmi(3), nutscan_display_ups_conf(3), nutscan_display_parsable(3), nutscan_new_device(3), nutscan_free_device(3), nutscan_add_option_to_device(3), nutscan_add_device_to_device(3), nutscan_get_serial_ports_list(3)
03/02/2016 | Network UPS Tools 2.7.3. |