Scroll to navigation

IRESET(8) System Manager's Manual IRESET(8)

NAME

ipmiutil_reset - perform a hardware reset on the system

SYNOPSIS

ipmiutil reset [-bcdDefhijmnoprsuwxy -N node -U user -P/-R pswd -EFJTVY]

DESCRIPTION

ipmiutil reset is a program that uses IPMI commands to perform a hardware reset of the chassis, or boot to a specific device. This utility can use either the /dev/ipmi0 driver from OpenIPMI, the /dev/imb driver from Intel, the /dev/ipmikcs driver from valinux, direct user-space IOs, or the IPMI LAN interface if -N.

OPTIONS

Command line options are described below.

Power Cycle the system chassis
Power Down the system chassis
Send NMI to the system
Power Up the system chassis
Hard Reset the system chassis
Do a soft shutdown of the OS, and then power down. Note that remote soft shutdown (-D -N) for Intel S5000 baseboard requires ipmiutil getevt -a running on the target server.
Do a soft shutdown of the OS, and then reset. Note that remote soft shutdown (-o -N) for Intel S5000 baseboard requires ipmiutil getevt -a running on the target server.
Do a cold reset to restart the BMC firmware.
Perform these function for a specific MC (e.g. bus 00, sa 20, lun 00). The trailing character, if present, indicates SMI addressing if 's', or IPMB addressing if 'i' or not present.
Do a hard reset and reboot to the BIOS Setup menu, for this reboot only.
Do a hard reset to EFI, if IPMI EFI boot is enabled, for this reboot only.
Do a hard reset to Floppy/Removable, for this reboot only.
Do a hard reset to a Hard Disk, for this reboot only.
Set the boot Initiator mailbox string, usually for PXE use. The string must be less than 78 characters.
Set the IANA number used for the boot Initiator mailbox string.
Do a hard reset and network boot to PXE server, for this reboot only.
Do a hard reset and reboot to the Service/Diagnostic Partition, for this reboot only. Reboots to the default if no service partition is configured.
Do a hard reset to DVD/CDROM Media, for this reboot only.
Wait for BMC ready after a reset before exiting the utility.
Causes extra debug messages to be displayed.
Yes, try to persist any boot options used [-befhprsv]. This requires the IPMI firmware to ask the BIOS to change boot order settings, so it may not be supported by all BMC firmware vendors.
Nodename or IP address of the remote target system. If a nodename is specified, IPMI LAN interface is used. Otherwise the local system management interface is used.
Remote password for the nodename given. The default is a null password.
Remote username for the nodename given. The default is a null username.
Use the remote password from Environment variable IPMI_PASSWORD.
Force the driver type to one of the followng: imb, va, open, gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means lan2 with intelplus. The default is to detect any available driver type and use it.
Use the specified LanPlus cipher suite (0 thru 17): 0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none, 3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40, 6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3.
Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2, 2=MD5, 4=Straight Password, 5=OEM.
Use a specified IPMI LAN privilege level. 1=Callback level, 2=User level, 3=Operator level, 4=Administrator level (default), 5=OEM level.
Yes, do prompt the user for the IPMI LAN remote password. Alternatives for the password are -E or -P.

SEE ALSO

ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8) ifru(8) igetevent(8) ihealth(8) ilan(8) isel(8) isensor(8) iserial(8) isol(8) iwdt(8)

WARNINGS

See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil and any bug fix list.

COPYRIGHT

Copyright (C) 2009 Kontron America, Inc.

See the file COPYING in the distribution for more details regarding redistribution.

This utility is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY.

AUTHOR

Andy Cress <arcress at users.sourceforge.net>

Version 1.5: 01 Jul 2011