Scroll to navigation

mDI001(3) One-Wire File System mDI001(3)

NAME

mDI001 - Digital Input Module

SYNOPSIS

Monitor 4 digital lines

A5 [.]XXXXXXXXXXXX[XX][/[ switch_closed.[0-3|ALL|BYTE] | loop_open.[0-3|ALL|BYTE] | loop_shorted.[0-3|ALL|BYTE] | address | crc8 | id | locator | r_address | r_id | r_locator | type ]]

FAMILY CODE

A5

SPECIAL PROPERTIES

switch_closed.[0-3|ALL|BYTE]

read-only, yes-no
Is the relay closed? (1=yes, 0=no).

Note that OWFS uses 0 through 3 as the index and the datasheet uses 1 through 4.

loop_shorted.[0-3|ALL|BYTE]

read-only, yes-no
Is the loop shorted? (1=yes, 0=no). Failsafe mode.

Note that OWFS uses 0 through 3 as the index and the datasheet uses 1 through 4.

loop_open.[0-3|ALL|BYTE]

read-only, yes-no
Is the loop open? (1=yes, 0=no). Failsafe mode.

Note that OWFS uses 0 through 3 as the index and the datasheet uses 1 through 4.

STANDARD PROPERTIES

address

r_address

read-only, ascii
The entire 64-bit unique ID. Given as upper case hexadecimal digits (0-9A-F).
address starts with the family code
r address is the address in reverse order, which is often used in other applications and labeling.

crc8

read-only, ascii
The 8-bit error correction portion. Uses cyclic redundancy check. Computed from the preceding 56 bits of the unique ID number. Given as upper case hexadecimal digits (0-9A-F).

family

read-only, ascii
The 8-bit family code. Unique to each type of device. Given as upper case hexadecimal digits (0-9A-F).

id

r_id

read-only, ascii
The 48-bit middle portion of the unique ID number. Does not include the family code or CRC. Given as upper case hexadecimal digits (0-9A-F).
r id is the id in reverse order, which is often used in other applications and labeling.

locator

r_locator

read-only, ascii
Uses an extension of the 1-wire design from iButtonLink company that associated 1-wire physical connections with a unique 1-wire code. If the connection is behind a Link Locator the locator will show a unique 8-byte number (16 character hexadecimal) starting with family code FE.
If no Link Locator is between the device and the master, the locator field will be all FF.
r locator is the locator in reverse order.

present (DEPRECATED)

read-only, yes-no
Is the device currently present on the 1-wire bus?

type

read-only, ascii
Part name assigned by Dallas Semi. E.g. DS2401 Alternative packaging (iButton vs chip) will not be distiguished.

ALARMS

None.

DESCRIPTION

1-Wire

1-wire is a wiring protocol and series of devices designed and manufactured by Dallas Semiconductor, Inc. The bus is a low-power low-speed low-connector scheme where the data line can also provide power.

Each device is uniquely and unalterably numbered during manufacture. There are a wide variety of devices, including memory, sensors (humidity, temperature, voltage, contact, current), switches, timers and data loggers. More complex devices (like thermocouple sensors) can be built with these basic devices. There are also 1-wire devices that have encryption included.

The 1-wire scheme uses a single bus master and multiple slaves on the same wire. The bus master initiates all communication. The slaves can be individually discovered and addressed using their unique ID.

Bus masters come in a variety of configurations including serial, parallel, i2c, network or USB adapters.

OWFS design

OWFS is a suite of programs that designed to make the 1-wire bus and its devices easily accessible. The underlying principle is to create a virtual filesystem, with the unique ID being the directory, and the individual properties of the device are represented as simple files that can be read and written.

Details of the individual slave or master design are hidden behind a consistent interface. The goal is to provide an easy set of tools for a software designer to create monitoring or control applications. There are some performance enhancements in the implementation, including data caching, parallel access to bus masters, and aggregation of device communication. Still the fundamental goal has been ease of use, flexibility and correctness rather than speed.

mDI001

The mDI001 (3) is used to monitor digital lines for simple switching.

ADDRESSING

All 1-wire devices are factory assigned a unique 64-bit address. This address is of the form:

8 bits
48 bits
8 bits

Addressing under OWFS is in hexadecimal, of form:

01.123456789ABC

where 01 is an example 8-bit family code, and 12345678ABC is an example 48 bit address.

The dot is optional, and the CRC code can included. If included, it must be correct.

WEBSITE

http://www.cmciel.com/products-solutions/individual-products/4-channel-fail-safe-digital-module-mdi001/

Programs

owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1) owwrite (1) owpresent (1) owtap (1)

Configuration and testing

owfs (5) owtap (1) owmon (1)

Language bindings

owtcl (3) owperl (3) owcapi (3)

Clocks

DS1427 (3) DS1904 (3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417 (3)

ID

DS2401 (3) DS2411 (3) DS1990A (3)

Memory

DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995 (3) DS1996 (3) DS2430A (3) DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3) DS28EC20 (3)

Switches

DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3) InfernoEmbedded (3)

Temperature

DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921 (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826 (3)

Humidity

DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)

Voltage

DS2450 (3)

Resistance

DS2890 (3)

Multifunction (current, voltage, temperature)

DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3) DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3)

Counter

DS2423 (3)

LCD Screen

LCD (3) DS2408 (3)

Crypto

DS1977 (3)

Pressure

DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3)

Moisture

EEEF (3) DS2438 (3)

AVAILABILITY

http://www.owfs.org

AUTHOR

Paul Alfille (paul.alfille@gmail.com)

2003 OWFS Manpage