Scroll to navigation

SMP_REP_PHY_EVENT(8) SMP_UTILS SMP_REP_PHY_EVENT(8)

NAME

smp_rep_phy_event - invoke REPORT PHY EVENT SMP function

SYNOPSIS

smp_rep_phy_event [--desc] [--enumerate] [--help] [--hex] [--interface=PARAMS] [--long] [--phy=ID] [--raw] [--sa=SAS_ADDR] [--verbose] [--version] [--zero] SMP_DEVICE[,N]

DESCRIPTION

Sends a SAS Serial Management Protocol (SMP) REPORT PHY EVENT function request to an SMP target. The SMP target is identified by the SMP_DEVICE and the SAS_ADDR. Depending on the interface, the SAS_ADDR may be deduced from the SMP_DEVICE. The mpt interface uses SMP_DEVICE to identify a HBA (an SMP initiator) and needs the additional ,N to differentiate between HBAs if there are multiple present.

Reports zero or more phy event descriptors. Each descriptor contains a phy event source, a phy event (i.e. a count) and a peak value detector theshold. At least one phy event should be maintained for each phy.

OPTIONS

Mandatory arguments to long options are mandatory for short options as well.

precede each phy event descriptor with a line announcing its descriptor index number. Index numbers start at 1.
enumerate all of the known Phy Event Source names, one per line preceded by its value in hex. Ignores SMP_DEVICE if it is given; most other options are also ignored. Exits after displaying the names.
output the usage message then exit.
output the response (less the CRC field) in hexadecimal.
interface specific parameters. In this case "interface" refers to the path through the operating system to the SMP initiator. See the smp_utils man page for more information.
prefix each phy event source string with its numeric identifier in hex. For example: "[0x1]: Invalid word count: 23"
phy identifier. ID is a value between 0 and 254. Default is 0.
send the response (less the CRC field) to stdout in binary. All error messages are sent to stderr.
specifies the SAS address of the SMP target device. Typically this is an expander. This option may not be needed if the SMP_DEVICE has the target's SAS address within it. The SAS_ADDR is in decimal but most SAS addresses are shown in hexadecimal. To give a number in hexadecimal either prefix it with '0x' or put a trailing 'h' on it.
increase the verbosity of the output. Can be used multiple times
print the version string and then exit.

NOTES

Similar information is maintained for SAS SSP target phys (e.g. on a SAS disk). It can be obtained from the Protocol Specific Port log page with the sg_logs utility.

Similar information may be obtained for SAS initiator phys (e.g. on a SAS HBA). As an example in Linux 2.6.28 error information can be found in this directory /sys/class/sas_phy/phy-4:0 (for the phy 0 in SCSI/SAS host 4).

Similar information may be obtained for SATA device phys (e.g. on a SATA disk). If there is a SAT layer between OS and the SATA device then the sg_sat_phy_event utility can fetch the information.

CONFORMING TO

The SMP REPORT PHY EVENT function was introduced in SAS-2 .

AUTHORS

Written by Douglas Gilbert.

REPORTING BUGS

Report bugs to <dgilbert at interlog dot com>.

COPYRIGHT

Copyright © 2011 Douglas Gilbert
This software is distributed under a FreeBSD license. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.

SEE ALSO

smp_utils, smp_phy_control, smp_rep_phy_event_list(smp_utils) sg_logs, sg_sat_phy_event(sg3_utils)

December 2011 smp_utils-0.97