table of contents
other versions
- buster 5.1.1-3
GENLIB_LOCON.3(October 1, 1997) | GENLIB_LOCON.3(October 1, 1997) |
NAME¶
GENLIB_LOCON - adds a logical connector to the current netlist figureSYNOPSYS¶
#include <genlib.h> void GENLIB_LOCON(connector, direction, signal); char ∗connector, ∗signal; char direction;
ORIGIN¶
This software belongs to the ALLIANCE CAD SYSTEM developed by the ASIM team at LIP6 laboratory of Université Pierre et Marie CURIE, in Paris, France.Web : http://asim.lip6.fr/recherche/alliance/
E-mail : alliance-users@asim.lip6.fr
PARAMETERS¶
- connector
- Name of the connector to be created in the current figure
- direction
- Indicates the connector behaviour regarding signals propagation
- signal
- Name of the signal on which the connector is linked
DESCRIPTION¶
LOCON add a logical connector to the interface of the actual working figure. This connector is logicaly linked to the signal signal. The direction attribut may take the following values:- IN
- as input.
- OUT
- as output.
- INOUT
- as input/output, like supplies or clock for example.
- UNKNOWN
- if one doesn't know what it is.
- TRISTATE
- as high impedance output.
- TRANSV
- as transciever. That means TRISTATE input plus output.
ERROR¶
"GENLIB_LOCON impossible : missing GENLIB_DEF_LOFIG"No figure has been yet specified by a call to
DEF_LOFIG. So it isn't possible to add anything. you must call
DEF_LOFIG before any other netlist call.
"GENLIB_LOCON : Bad signal or connector bus name"
A signal or connector, described under a bus form, has an
illegal syntax.
- "GENLIB_LOCON : All LOCON should be defined befor any GENLIB_LOINS"
A connector is added after instances. This is a
methodological error. Only move your LOCON before the first
LOINS in your code.
"GENLIB_LOCON : different number of signals and connectors"
A bussed form of signal and connector has been used, but
the width of the busses are not equal. This is an obvious error, check
it.
"Illegal addlocon. Connector connector already exist in figure
figname"
A connector name must be unique in a given figure at a
given hierachy level.
DIAGNOSTICS¶
Due to the vti file format, the direction of connectors is lost if one uses it as starting point of a netlist desciption. All the connectors have then the UNKNOWN direction.Alliance and edif file format know only about IN, OUT, and UNKNOWN. Only vhdl format fully supports the whole thing.
EXAMPLE¶
#include <genlib.h> main() { /∗ Create a figure to work on ∗/ GENLIB_DEF_LOFIG("mycell"); /∗ define interface ∗/ GENLIB_LOCON("i", INPUT, "sig1"); GENLIB_LOCON("o", OUTPUT, "sig2"); /∗ Place an instance ∗/ GENLIB_LOINS("model","instance", "sig1", "sig2", EOL); /∗ Save all that on disk ∗/ GENLIB_SAVE_LOFIG(); }
SEE ALSO¶
genlib(1), GENLIB_BUS(3), GENLIB_ELM(3), GENLIB_LOSIG(3), GENLIB_LOINS(3).BUG REPORT¶
This tool is under development at the ASIM department of the LIP6 laboratory.We need your feedback to improve documentation and tools.
ASIM/LIP6 | PROCEDURAL GENERATION LANGUAGE |