NAME¶
hpialarms - A openhpi sample application that shows "Alarm Control"
management instruments
SYNOPSIS¶
hpialarms [-D id] [-N host[:port]] [-C <cfgfile>]
[-a 1|0][-b 1|0][-c 1|0][-m 1|0][-n 1|0][-p 1|0][-i n][-o][-X][-h]
hpialarms [--domain=id] [--host=host[:port]] [--cfgfile=file]
[--diska=1|0] [--diskb=1|0] [--critical=1|0] [--major=1|0]
[--minor=1|0] [--power=1|0] [--chassisid=n] [--all] [--debug] [--help]
DESCRIPTION¶
hpialarms walks the RPT (Resource Presence Table) for resources that have
"Alarm Control" management instruments (SAHPI_CTRL_LED).
If no domain or host is selected, hpialarms uses the default
domain as specified in the openhpiclient.conf file.
OPTIONS¶
(No Option) Display alarm states
Help Options:¶
- -h, --help
- Show help options
Application Options:¶
- -c 1|0, --critical=1|0
- Set critical alarm on|off
- -m 1|0, --major=1|0
- Set major alarm on|off
- -n 1|0, --minor=1|0
- Set minor alarm on|off
- -a 1|0, --diska=1|0
- Set diska alarm on|off
- -b 1|0, --diskb=1|0
- Set diskb alarm on|off
- -p 1|0, --power=1|0
- Set power alarm on|off
- -i n, --chassisid=n
- Set chassis id on for n seconds
- -o, --all
- Set all alarms off
- -D nn, --domain=nn
- Select domain id nn
- -X, --debug
- Display debug messages
- -N "host[:port]",
--host="host[:port]"
- Open session to the domain served by the daemon at the specified URL
(host:port). This option overrides the OPENHPI_DAEMON_HOST and
OPENHPI_DAEMON_PORT environment variables. If host contains ':' (for
example IPv6 address) then enclose it in square brackets. For example:
"[::1]" or "[::1]:4743".
- -C "file",
--cfgfile="file"
- Use passed file as client configuration file. This option overrides the
OPENHPICLIENT_CONF environment variable.
SAMPLE OUTPUT¶
hpialarmpanel ver 0.6
RptInfo: UpdateCount = 5, UpdateTime = 8a2dc6c0
rptentry[0] resourceid=1 tag: Mullins
RDR[45]: ctltype=2:1 oem=0 Chassis Identify Control
RDR[48]: ctltype=0:1 oem=10 Front Panel Power Alarm LED state = off
RDR[51]: ctltype=0:1 oem=13 Front Panel Minor Alarm LED state = ON
RDR[46]: ctltype=0:0 oem=0 Cold Reset Control
RDR[49]: ctltype=0:1 oem=11 Front Panel Critical Alarm LED state = off
RDR[50]: ctltype=0:1 oem=12 Front Panel Major Alarm LED state = off
SEE ALSO¶
hpi_shell
hpidomain hpigensimdata hpireset hpitop
hpiel hpiinv hpisensor hpitree
hpievents hpionIBMblade hpisettime hpiwdt
hpifan hpipower hpithres hpixml
ohdomainlist ohhandler ohparam
AUTHORS¶
Authors of this man page:
Peter D Phan (pdphan@users.sourceforge.net)
Ulrich Kleber (ulikleber@users.sourceforge.net)
Anton Pak (avpak@users.sourceforge.net)