NAME¶
  - EDS
 
  - - Embedded Data Systems Sensors
 
  - EDS0064
 
  - Temperature
 
  - EDS0065
 
  - Temperature and Humidity
 
  - EDS0066
 
  - Temperature and Barometric Pressure
 
  - EDS0067
 
  - Temperature and Light
 
  - EDS0068
 
  - Temperature, Barometric Pressure and Light
 
  - EDS0070
 
  - Vibration
 
  - EDS0071
 
  - RTD 4-wire temperature
 
  - EDS0072
 
  - RTD 3-wire temperature
 
  - EDS0080
 
  - 8 Channel Analog Current Input
 
  - EDS0082
 
  - 8 Channel Analog Voltage Input
 
  - EDS0083
 
  - 4 Channel Analog Current Input
 
  - EDS0085
 
  - 4 Channel Analog Voltage Input
 
  - EDS0090
 
  - 8 Discrete I/O
 
SYNOPSIS¶
Embedded Data Systems microprocessor-based sensors
Sub-type ( all )¶
7E [.]XXXXXXXXXXXX[XX][/[ 
device_id | 
device_type |
  
tag ]]
Memory ( all )¶
7E [.]XXXXXXXXXXXX[XX][/[ 
memory | 
pages/page.[0-2|ALL] ]]
Standard ( all )¶
7E [.]XXXXXXXXXXXX[XX][/[ 
address | 
crc8 | 
id |
  
locator | 
r_address | 
r_id | 
r_locator |
  
type ]]
Temperature ( EDS0064/5/6/7/8 )¶
7E.XXXXXXXXXXXX/EDS006X [/[ 
temperature | 
counters/seconds
  | 
alarm/temp_[hi|low] | 
alarm/clear |
  
set_alarm/temp_[hi|low] | 
threshold/temp_[hi|low] ]]
Humidity ( EDS0065/8 )¶
7E.XXXXXXXXXXXX/EDS006X [/[ 
humidity | 
humidex |
  
dew_point | 
heat_index | 
alarm/humidity_[hi|low] |
  
alarm/humidex_[hi|low] | 
alarm/dew_point_[hi|low] |
  
alarm/heat_index_[hi|low] | 
alarm/clear |
  
set_alarm/humidity_[hi|low] | 
set_alarm/humidex_[hi|low] |
  
set_alarm/dew_point_[hi|low] | 
set_alarm/heat_index_[hi|low] |
  
threshold/humidity_[hi|low] |
 
threshold/humidex_[hi|low] | 
threshold/dew_point_[hi|low] |
  
threshold/heat_index_[hi|low] ]]
Barometric Pressure ( EDS0066/8 )¶
7E.XXXXXXXXXXXX/EDS006X [/[ 
pressure | 
inHg |
  
alarm/pressure_[hi|low] | 
alarm/inHg_[hi|low] |
  
alarm/clear | 
set_alarm/pressure_[hi|low] |
  
set_alarm/inHg_[hi|low] | 
threshold/pressure_[hi|low] |
  
threshold/inHg_[hi|low] ]]
Light ( EDS0067/8 )¶
7E.XXXXXXXXXXXX/EDS006X [/[ 
light | 
alarm/light_[hi|low] |
  
alarm/clear | 
set_alarm/light_[hi|low] |
  
threshold/light_[hi|low] ]]
Vibration ( EDS0070 )¶
7E.XXXXXXXXXXXX/EDS0070 [/[ 
vib_level | 
vib_peak |
  
vib_min | 
vib_max | 
counter/seconds |
  
alarm/vib_[hi|low] | 
alarm/clear | 
set_alarm/vib_[hi|low]
  | 
threshold/vib_[hi|low] ]]
RTD Temperature ( EDS0071/2 )¶
7E.XXXXXXXXXXXX/EDS007X [/[ 
temperature | 
resistance |
  
raw | 
delay | 
user_byte |
  
calibration/[key|constant] | 
counter/[seconds|samples] |
  
alarm/temp_[hi|low] | 
alarm/RTD_[hi_low] | 
alarm/clear |
  
set_alarm/temp_[hi|low] | 
set_alarm/RTD_[hi_low] |
  
threshold/temp_[hi|low] | 
threshold/RTD_[hi_low] ]]
Analog Current ( EDS0080 [0-7] EDS0083 [0-3] )¶
7E.XXXXXXXXXXXX/EDS0080 [/[ 
current.[0-7|ALL] |
  
max_current.[0-7|ALL] | 
min_current.[0-7|ALL] |
  
threshold/current_hi.[0-7|ALL] | 
threshold/current_low.[0-7|ALL]
  | 
alarm/current_hi.[0-7|ALL|BYTE] |
  
alarm/current_low.[0-7|ALL|BYTE] |
  
set_alarm/current_hi.[0-7|ALL|BYTE] |
  
set_alarm/current_low.[0-7|ALL|BYTE] | 
counter/seconds |
  
memory | 
pages/page.[0-4|ALL]
Analog Voltage ( EDS0082 [0-7] EDS0085 [0-3] )¶
7E.XXXXXXXXXXXX/EDS0082 [/[ 
volts.[0-7|ALL] |
  
max_volts.[0-7|ALL] | 
min_volts.[0-7|ALL] |
  
threshold/volts_hi.[0-7|ALL] | 
threshold/volts_low.[0-7|ALL] |
  
alarm/volts_hi.[0-7|ALL|BYTE] | 
alarm/volts_low.[0-7|ALL|BYTE] |
  
set_alarm/volts_hi.[0-7|ALL|BYTE] |
  
set_alarm/volts_low.[0-7|ALL|BYTE] | 
counter/seconds |
  
memory | 
pages/page.[0-4|ALL]
I/O ( EDS0090 )¶
7E.XXXXXXXXXXXX/EDS009X [/[ 
input.[0-7|ALL] | 
counter/[seconds
  | pulses.[0-7|ALL]|reset.[0-7|ALL|BYTE]] |
  
output/[set.[0-7|ALL|BYTE]|off.[0-7|ALL|BYTE]|reset.[0-7|ALL|BYTE]] |
  
latch/[state.[0-7|ALL|BYTE]|reset.[0-7|ALL|BYTE]] |
  
alarm/[hi.[0-7|ALL]|low.[0-7|ALL]|clear] |
  
set_alarm/[hi.[0-7|ALL]|low.[0-7|ALL]]
LED ( all )¶
7E.XXXXXXXXXXXX/EDS00XX/LED/[state|control]
relay ( all )¶
7E.XXXXXXXXXXXX/EDS00XX/relay/[state|control]
FAMILY CODE¶
  - 7E
 
  
TEMPERATURE¶
EDS006X/temperature¶
read-only, floating-point
 
Temperature for the EDS006X series of chips. In the -55C to 125C range, with
  0.0636C precision. The temperature is read every second, continually. Data is
  presented in the specified temperature scale, Celsius by default.
EDS007X/temperature¶
read-only, floating-point
 
Temperature for the EDS007X series of chips. Read using a wide-range precise RTD
  sensor. Typical range is -60C to 260C with 0.15C accuracy, although a range of
  -200C to 850C is possible. The temperature is read every second unless a
  longer 
EDS007X/delay is given. Data is presented in the specified
  temperature scale, Celsius by default.
EDS007X/resistance¶
read-only, floating-point
 
Actual measured resistance (Ohms) of the RTD element. Useful if the RTD element
  doesn't conform to the typical European IEC 60751 standard.
HUMIDITY¶
EDS006X/humidity¶
read-only, floating-point
 
Relative humidity in the 0-100 range (percent). Read every 0.2 seconds.
EDS006X/dew_point¶
read-only, floating-point
 
Dew point computed from 
EDS006X/temperature and 
EDS006X/humidity
  computered every 0.2 seconds. Data is a calculated temperature and is reported
  in the specified temperature scale. Default Celsius.
EDS006X/heat_index¶
read-only, floating-point
 
Heat index computed from 
EDS006X/temperature and 
EDS006X/humidity
  computered every 0.2 seconds. Data is a calculated temperature and is reported
  in the specified temperature scale. Default Celsius.
EDS006X/humidex¶
read-only, floating-point
 
Humidex (popular in Canada) computed from 
EDS006X/temperature and
  
EDS006X/humidity computed every 0.2 seconds. Data is a percent and
  reported in the 0-100 range.
LIGHT¶
EDS006X/light¶
read-only, unsigned integer
 
Ambient light in Lux. Measured every 0.2 seconds.
PRESSURE¶
EDS006X/pressure¶
read-only, floating-point
 
Ambient pressure, measured every 0.2 seconds. Data in the selected pressure
  scale (default mBar).
EDS006X/inHg¶
read-only, floating-point
 
Ambient pressure, measured every 0.2 seconds. Data in the inHg scale.
VIBRATION¶
EDS0070/vib_level¶
read_only, unsigned integer
 
Vibration registered by sensor (instantaneous value) in 0-1023 range.
EDS0070/vib_peak¶
read_only, unsigned integer
 
Vibration registered by sensor (highest recent value -- slowly decays) in 0-1023
  range.
EDS0070/vib_min¶
read_only, unsigned integer
 
Vibration registered by sensor (lowest value) in 0-1023 range.
EDS0070/vib_max¶
read_only, unsigned integer
 
Vibration registered by sensor (highest value) in 0-1023 range.
CURRENT¶
The 
EDS0080 and 
EDS0083 measure current in the 4-20mA range, with
  upper and threshold limits and the ability to set an alarm and independently
  trigger a relay if the value is out of range.
EDS0080/current.[0-7|ALL] EDS0083/current.[0-3|ALL]¶
read-only, floating point
 
Current current level. (4-20mA)
EDS0080/max_current.[0-7|ALL] EDS0080/max_current.[0-3|ALL]¶
EDS0083/min_current.[0-7|ALL] EDS0083/min_current.[0-3|ALL]¶
read-only, floating point
 
Maximum and minimum current readings since last 
alarm/clear command.
VOLTAGE¶
The 
EDS0082 and 
EDS0085 measure voltage in the 0-10V range, with
  upper and threshold limits and the ability to set an alarm and independently
  trigger a relay if the value is out of range.
EDS0082/volts.[0-7|ALL] EDS0085/volts.[0-3|ALL]¶
read-only, floating point
 
Current voltage level. (0-10V)
EDS0082/max_volts.[0-7|ALL] EDS0085/max_volts.[0-3|ALL]¶
EDS0082/min_volts.[0-7|ALL] EDS0085/min_volts.[0-3|ALL]¶
read-only, floating point
 
Maximum and minimum voltage readings since last 
alarm/clear command.
THRESHOLD¶
High and low range of acceptable sensor readings. Values outside this range will
  trigger an alarm if the corresponding 
EDS00XX/set_alarm flag is set.
EDS00XX/threshold/temp_hi EDS00XX/threshold/temp_low¶
read-write, floating-point
 
Threshold temperatures in the specified temperature scale. Default Celsius.
EDS006X/threshold/humidity_hi 	EDS006X/threshold/humidity_low¶
EDS006X/threshold/dew_point_hi 	EDS006X/threshold/dew_point_low¶
EDS006X/threshold/heat_index_hi 	EDS006X/threshold/heat_index_low¶
EDS006X/threshold/humidex_hi 	EDS006X/threshold/humidex_low¶
read-write, floating-point
 
Threshold humidity values. 
Dew point and 
Heat index are in the
  specified temperature scale. Default Celsius.
EDS006X/threshold/pressure_hi 	EDS006X/threshold/pressure_low¶
EDS006X/threshold/inHg_hi 	EDS006X/threshold/inHg_low¶
read-write, floating-point
 
Threshold barometric pressure values. 
Pressure is the specified pressure
  scale. Default mBar.
EDS006X/threshold/light_hi 	EDS006X/threshold/light_low¶
read-write, unsigned
 
Threshold light (lux) values.
EDS0070/threshold/vib_hi 	EDS0070/threshold/vib_low¶
read-write, unsigned
 
Vibration sensor alarm limits in 0-1023 range.
EDS007X/threshold/resistance_hi 	EDS007X/threshold/resistance_low¶
read-write, floating-point
 
Threshold RTD resistance values (Ohm).
EDS0080/threshold/current_hi.[0-7|ALL]¶
EDS0080/threshold/current_low.[0-7|ALL]¶
EDS0082/threshold/volts_hi.[0-7|ALL]¶
EDS0082/threshold/volts_low.[0-7|ALL]¶
EDS0083/threshold/current_hi.[0-3|ALL]¶
EDS0083/threshold/current_low.[0-3|ALL]¶
EDS0085/threshold/volts_hi.[0-3|ALL]¶
EDS0085/threshold/volts_low.[0-3|ALL|]¶
read-write, floating-point
 
Voltage or current threshold limits
SET ALARM¶
Set conditional alarm to trigger if corresponding flag is set. Also must set
  high and low 
threshold.
EDS00XX/set_alarm/temp_hi 	EDS00XX/set_alarm/temp_low¶
EDS006X/set_alarm/humidity_hi 	EDS006X/set_alarm/humidity_low¶
EDS006X/set_alarm/dew_point_hi 	EDS006X/set_alarm/dew_point_low¶
EDS006X/set_alarm/heat_index_hi 	EDS006X/set_alarm/heat_index_low¶
EDS006X/set_alarm/humidex_hi 	EDS006X/set_alarm/humidex_low¶
EDS006X/set_alarm/pressure_hi 	EDS006X/set_alarm/pressure_low¶
EDS006X/set_alarm/inHg_hi 	EDS006X/set_alarm/inHg_low¶
EDS006X/set_alarm/light_hi 	EDS006X/set_alarm/light_low¶
EDS0070/set_alarm/vib_hi 	EDS0070/set_alarm/vib_low¶
EDS007X/set_alarm/resistance_hi 	EDS007X/set_alarm/resistance_low¶
EDS0080/set_alarm/current_hi.[0-7|ALL|BYTE]¶
EDS0080/set_alarm/current_low.[0-7|ALL|BYTE]¶
EDS0082/set_alarm/volts_hi.[0-7|ALL|BYTE]¶
EDS0082/set_alarm/volts_low.[0-7|ALL|BYTE]¶
EDS0083/set_alarm/current_hi.[0-3|ALL|BYTE]¶
EDS0083/set_alarm/current_low.[0-3|ALL|BYTE]¶
EDS0085/set_alarm/volts_hi.[0-3|ALL|BYTE]¶
EDS0085/set_alarm/volts_low.[0-3|ALL|BYTE]¶
read-write, yes-no
 
Flag to set corresponding out-of-range alarm. "1" turns on flag, and
  "0" turns off.
ALARM¶
Show or clear the out-of-range flags. When set, the device will respond to a
  conditional search. Clearing the flags is performed with the
  
EDS00XX/alarm/clear command, not just having the measured value return
  to the center range.
EDS00XX/alarm/clear¶
write-only, yes-no
 
Write "1" to clear 
ALL the alarm flags.
EDS00XX/alarm/temp_hi 	EDS00XX/alarm/temp_low¶
EDS006X/alarm/humidity_hi 	EDS006X/alarm/humidity_low¶
EDS006X/alarm/dew_point_hi 	EDS006X/alarm/dew_point_low¶
EDS006X/alarm/heat_index_hi 	EDS006X/alarm/heat_index_low¶
EDS006X/alarm/humidex_hi 	EDS006X/alarm/humidex_low¶
EDS006X/alarm/pressure_hi 	EDS006X/alarm/pressure_low¶
EDS006X/alarm/inHg_hi 	EDS006X/alarm/inHg_low¶
EDS006X/alarm/light_hi 	EDS006X/alarm/light_low¶
EDS0070/alarm/vib_hi 	EDS007X/alarm/vib_low¶
EDS007X/alarm/resistance_hi 	EDS007X/alarm/resistance_low¶
EDS0080/alarm/current_hi.[0-7|ALL|BYTE]¶
EDS0080/alarm/current_low.[0-7|ALL|BYTE]¶
EDS0082/alarm/volts_hi.[0-7|ALL|BYTE]¶
EDS0082/alarm/volts_low.[0-7|ALL|BYTE]¶
EDS0083/alarm/current_hi.[0-3|ALL|BYTE]¶
EDS0083/alarm/current_low.[0-3|ALL|BYTE]¶
EDS0085/alarm/volts_hi.[0-3|ALL|BYTE]¶
EDS0085/alarm/volts_low.[0-3|ALL|BYTE]¶
EDS0090/alarm/hi[0-7|ALL] 	EDS0090/alarm/low[0-7|ALL]¶
read-only, yes-no
 
Show corresponding out-of-range alarm. "1" means in alarm state. Can
  only be turned off with 
clear
RELAY¶
Optionally found on the EDS006X and EDS007X. Can be controlled by software or
  the alarm condition.
EDS00XX/relay/control¶
read-write, unsigned
 
Set the relay control scheme:
  - 0
 
  - alarm control with hysteresis
 
  - 1
 
  - alarm control but need EDS00XX/alarm/clear to unset
 
  - 2
 
  - Control with EDS00XX/relay/state
 
  - 3
 
  - Always off
 
EDS00XX/relay/state¶
read-write, yes-no
 
Turn the relay on or off if the 
EDS00XX/relay/control is set to 2
LED light¶
Found on the EDS006X and EDS007X. Can be controlled by software or the alarm
  condition.
EDS00XX/LED/control¶
read-write, unsigned
 
Set the LED control scheme:
  - 0
 
  - alarm control with hysteresis
 
  - 1
 
  - alarm control but need EDS00XX/alarm/clear to unset
 
  - 2
 
  - Control with EDS00XX/LED/state
 
  - 3
 
  - Always off
 
EDS00XX/LED/state¶
read-write, yes-no
 
Turn the LED on or off if the 
EDS00XX/LED/control is set to 2
COUNTER¶
EDS00XX/counter/seconds¶
read-only, unsigned integer
 
Approximate seconds since power up.
EDS0090/counter/pulses.0-7 | ALL¶
read-only, unsigned integer
 
Pulses on each channel since power up or reset. Channel should be set to input (
  
EDS0090/output/set.x =0 )
EDS0090/counter/reset.0-7 | ALL | BYTE¶
read-write, yes-no
 
Clear the pulse count on the corresponding channel.
EDS007X/counter/samples¶
read-only, unsigned integer
 
Approximate samples since power up.
MEMORY¶
memory¶
read-write, binary
 
96 bytes of memory. Not all is writable. Access to 
EDS00XX functions is
  better accomplished through the data fields, which expose all the chip
  features.
pages/page.0 ... pages/page.2 pages/page.ALL¶
read-write, binary
 
Memory is split into 3 pages of 32 bytes each. Only page 2 is writable.
  
ALL is an aggregate of the pages. Each page is accessed sequentially.
EDS008X/memory¶
read-write, binary
 
160 bytes of memory. Not all is writable. Access to 
EDS008X functions is
  better accomplished through the data fields, which expose all the chip
  features. The 
EDS008X has more memory than the other chips, so a
  separate entry in the sudbirectory makes it available.
EDS008X/pages/page.0-4 EDS008X/pages/page.ALL¶
read-write, binary
 
Memory is split into 5 pages of 32 bytes each. Only page 5 is writable. The
  
EDS008X has more memory than the other chips, so a separate entry in
  the sudbirectory makes the extra pages available. 
ALL is an aggregate
  of the pages. Each page is accessed sequentially.
SUB-TYPE¶
tag¶
read-only, ascii
 
Text description of the device. Up to 30 characters.
device_type¶
read-only, ascii
 
Device name. E.g: "EDS0071"
device_id¶
read-only, unsigned
 
Number corresponding to the hexidecimal type. E.g:
 
EDS0071 -> 0x0071 -> 113 in decimal
STANDARD PROPERTIES¶
address¶
r_address¶
read-only, ascii
 
The entire 64-bit unique ID. Given as upper case hexidecimal digits (0-9A-F).
 
address starts with the 
family code
 
r address is the 
address in reverse order, which is often used in
  other applications and labeling.
crc8¶
read-only, ascii
 
The 8-bit error correction portion. Uses cyclic redundancy check. Computed from
  the preceding 56 bits of the unique ID number. Given as upper case hexidecimal
  digits (0-9A-F).
family¶
read-only, ascii
 
The 8-bit family code. Unique to each 
type of device. Given as upper case
  hexidecimal digits (0-9A-F).
r_id¶
read-only, ascii
 
The 48-bit middle portion of the unique ID number. Does not include the family
  code or CRC. Given as upper case hexidecimal digits (0-9A-F).
 
r id is the 
id in reverse order, which is often used in other
  applications and labeling.
locator¶
r_locator¶
read-only, ascii
 
Uses an extension of the 1-wire design from iButtonLink company that associated
  1-wire physical connections with a unique 1-wire code. If the connection is
  behind a 
Link Locator the 
locator will show a unique 8-byte number
  (16 character hexidecimal) starting with family code FE.
 
If no 
Link Locator is between the device and the master, the
  
locator field will be all FF.
 
r locator is the 
locator in reverse order.
present (DEPRECATED)¶
read-only, yes-no
 
Is the device currently 
present on the 1-wire bus?
type¶
read-only, ascii
 
Part name assigned by Dallas Semi. E.g. 
DS2401 Alternative packaging
  (iButton vs chip) will not be distiguished.
ALARMS¶
None.
DESCRIPTION¶
1-Wire¶
1-wire is a wiring protocol and series of devices designed and
  manufactured by Dallas Semiconductor, Inc. The bus is a low-power low-speed
  low-connector scheme where the data line can also provide power.
Each device is uniquely and unalterably numbered during manufacture. There are a
  wide variety of devices, including memory, sensors (humidity, temperature,
  voltage, contact, current), switches, timers and data loggers. More complex
  devices (like thermocouple sensors) can be built with these basic devices.
  There are also 1-wire devices that have encryption included.
The 1-wire scheme uses a single 
bus master and multiple 
slaves on
  the same wire. The bus master initiates all communication. The slaves can be
  individually discovered and addressed using their unique ID.
Bus masters come in a variety of configurations including serial, parallel, i2c,
  network or USB adapters.
OWFS design¶
OWFS is a suite of programs that designed to make the 1-wire bus and its
  devices easily accessible. The underlying priciple is to create a virtual
  filesystem, with the unique ID being the directory, and the individual
  properties of the device are represented as simple files that can be read and
  written.
Details of the individual slave or master design are hidden behind a consistent
  interface. The goal is to provide an easy set of tools for a software designer
  to create monitoring or control applications. There are some performance
  enhancements in the implementation, including data caching, parallel access to
  bus masters, and aggregation of device communication. Still the fundemental
  goal has been ease of use, flexibility and correctness rather than speed.
EDS00XX Overview¶
The EDS00XX sensors are a family of devices from 
Embedded Data Systems.
  Although provisional support for several types is included, only early
  
EDS0071 has been tested with 
OWFS.
The sensors all share the same 
7E family code. They have the same first
  memory page layout with a text 
tag property that describes them, and a
  
sub-type field giving the particular sensor. The data properties shown
  in a directory listing will be specific to the sensor 
sub-type.
EDS0071¶
The 
EDS0071 (3) is a micro-processor based 1-wire slave made by EDS
  (Embedded Data Systams). Is uses a high accuracy and extended range RTD sensor
  to accurately measure temperatures.
Memory¶
The 
EDS00XX sensors are read and controlled by accessing parts of their
  on-chip memory. Although the raw memory contents are exposed in the
  
memory and 
pages fields, all the available functionality is best
  accessed by the other fields. In fact, directly changing memory will confuse
  
OWFS.
Relay and LED¶
All the 
EDS00XX sensors have an LED and optional relay. Both can be
  controlled either directly, or when the sensors reaches an alarm state.
ADDRESSING¶
All 1-wire devices are factory assigned a unique 64-bit address. This address is
  of the form:
  - Family Code
 
  - 8 bits
 
  - Address
 
  - 48 bits
 
  - CRC
 
  - 8 bits
 
Addressing under OWFS is in hexidecimal, of form:
  
  - 01.123456789ABC
 
where 
01 is an example 8-bit family code, and 
12345678ABC is an
  example 48 bit address.
The dot is optional, and the CRC code can included. If included, it must be
  correct.
DATASHEET¶
  - EDS0064 EDS0065 EDS0066 EDS0067 EDS0068
 
  - https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&srcid=0B_K3iXLLAI7vN2E4NGUwMGItMzc5MS00NDNmLTljZGYtN2NmM2Q3YWE5NmVh&hl=en
 
  - EDS0070
 
  - http://www.embeddeddatasystems.com/assets/images/supportFiles/manuals/EN-UserMan%20%20OW-Vibration%20V01.pdf
 
  - EDS0071 EDS0072
 
  - https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&srcid=0B_K3iXLLAI7vMjVhNWQzYzItZTRhMi00NGY2LWI4NTQtYjZlYTgzYzY0NmNm&hl=en
 
  - EDS0080 EDS0083
 
  - https://eds.zendesk.com/attachments/token/ulnpj6mvpp6yzwo/?name=EN-USERMAN+OW-IO-AIX-420+v1p0.pdf
 
  - EDS0082 EDS0085
 
  - https://eds.zendesk.com/attachments/token/vyai6ylpw6edala/?name=EN-USERMAN+OW-IO-AIX-10V+v1p0.pdf
 
  - EDS0090
 
  - 8 Discrete I/O
 
SEE ALSO¶
Programs¶
owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1)
  owwrite (1) owpresent (1) owtap (1)
Configuration and testing¶
owfs (5) owtap (1) owmon (1)
Language bindings¶
owtcl (3) owperl (3) owcapi (3)
Clocks¶
DS1427 (3) DS1904(3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417
  (3)
DS2401 (3) DS2411 (3) DS1990A (3)
Memory¶
DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995 (3)
  DS1996 (3) DS2430A (3) DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3)
  DS28EC20 (3)
Switches¶
DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3)
Temperature¶
DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921
  (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3)
  EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826 (3)
Humidity¶
DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)
Voltage¶
DS2450 (3)
Resistance¶
DS2890 (3)
Multifunction (current, voltage, temperature)¶
DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3)
  DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3)
Counter¶
DS2423 (3)
LCD Screen¶
LCD (3) DS2408 (3)
Crypto¶
DS1977 (3)
Pressure¶
DS2406 (3) TAI8570 EDS0066 (3) EDS0068 (3)
Moisture¶
EEEF (3) DS2438 (3)
AVAILABILITY¶
http://www.owfs.org
AUTHOR¶
Paul Alfille (paul.alfille@gmail.com)