NAME¶
sesman.ini - Configuration file for
sesman(8)
DESCRIPTION¶
This is the man page for
sesman.ini,
sesman(8) configuration file.
It is composed by a number of sections, each one composed by a section name,
enclosed by square brackets, folowed by a list of
<parameter>=
<value> lines.
sesman.ini supports the following sections:
- [Globals] - sesman global configuration section,
-
- [Logging] - logging subsystem parameters
-
- [Security] - Access control parameters
-
- [Sessions] - Session management parameters
-
All options and values (except for file names and paths) are case insensitive,
and are described in detail below.
For any of the following parameter, if it's specified more than one time the
last entry encountered will be used.
NOTE: if any of these options is specified outside its section, it will
be
ignored.
GLOBALS¶
- The options to be specified in the [globals] section are the
following:
-
- ListenAddress=ip address
- Specifies sesman listening address. Default is 0.0.0.0 (all interfaces)
- ListenPort=port number
- Specifies sesman listening port. Default is 3350
- EnableUserWindowManager=[0|1]
- If set to 1, true or yes this option enables user
specific window manager, that is, anyone can define it's own script
executed by sesman when starting a new session, specified by
UserWindowManager
- UserWindowManager=startwm.sh
- This option specifies the script run by sesman when starting a session and
per-user window manager is enabled.
The path is relative to user's HOME directory
- DefaultWindowManager=${SESMAN_BIN_DIR}/startwm.sh
- This contains full path to the default window manager startup script used
by sesman to start a session
LOGGING¶
- The following parameters can be used in the [logging] section:
-
- LogFile=${SESMAN_LOG_DIR}/sesman.log
- This options contains the path to logfile. It can be either absolute or
relative, and the default is ${SESMAN_LOG_DIR}/sesman.log
- LogLevel=level
- This option can have one of the following values:
CORE or 0 - Log only core messages. these messages are
_always_ logged, regardless the logging level selected.
ERROR or 1 - Log only error messages
WARNING, WARN or 2 - Logs warnings and error messages
INFO or 3 - Logs errors, warnings and informational messages
DEBUG or 4 - Log everything. If sesman is compiled in
debug mode, this options will output many more low-level message, useful
for developers
- EnableSyslog=[0|1]
- If set to 1, true or yes this option enables logging
to syslog. Otherwise syslog is disabled.
- SyslogLevel=level
- This option sets the logging level for syslog. It can have the same values
of LogLevel. If SyslogLevel is greater than LogLevel,
its value is lowered to that of LogLevel.
SESSIONS¶
- The following parameters can be used in the [Sessions]
section:
-
- X11DisplayOffset=<number>
- Specifies the first X display number available for sesman(8). This
prevents sesman from interfering with real X11 servers. The default is 10.
- MaxSessions=<number>
- Sets the maximum number of simultaneous session on terminal server.
If unset or set to 0, unlimited session are allowed.
- KillDisconnected=[0|1]
- If set to 1, true or yes, every session will be
killed when the user disconnects.
-this option is currently ignored!-
- IdleTimeLimit=<number>
- Sets the the time limit before an idle session is disconnected.
If set to 0, automatic disconnection is disabled.
-this option is currently ignored!-
- DisconnectedTimeLimit=<number>
- Sets the the time limit before a disconnected session is killed.
If set to 0, automatic killing is disabled.
-this option is currently ignored!-
SECURITY¶
- The following parameters can be used in the [Sessions]
section:
-
- AllowRootLogin=[0|1]
- If set to 1, true or yes enables root login on the
terminal server
- MaxLoginRetry=[0|1]
- The number of login attempts that are allowed on terminal server. If set
to 0, unlimited attempts are allowed. The default value for this
field is 3.
- TerminalServerUsers=tsusers
- Only the users belonging to the group tsusers are allowed to login
on terminal server.
If unset or set to an invalid or non-existent group, login for all users is
enabled.
- TerminalServerAdmins=tsadmins
- Sets the group which a user shall belong to have session management
rights.
-this option is currently ignored!-
EXAMPLES¶
This is an example
sesman.ini:
[Globals]
ListenAddress=127.0.0.1
ListenPort=3350
EnableUserWindowManager=1
UserWindowManager=startwm.sh
DefaultWindowManager=startwm.sh
[Logging]
LogFile=/usr/local/xrdp/sesman.log
LogLevel=DEBUG
EnableSyslog=0
SyslogLevel=DEBUG
[Sessions]
MaxSessions=10
KillDisconnected=0
IdleTimeLimit=0
DisconnectedTimeLimit=0
[Security]
AllowRootLogin=1
MaxLoginRetry=3
TerminalServerUsers=tsusers
TerminalServerAdmins=tsadmins
FILES¶
${SESMAN_CFG_DIR}/sesman.ini
SEE ALSO¶
sesman(8) sesrun(8)
xrdp(8) xrdp.ini(5)
for more info on
xrdp see
http://xrdp.sf.net