table of contents
SNMP::Info::CiscoPower(3pm) | User Contributed Perl Documentation | SNMP::Info::CiscoPower(3pm) |
NAME¶
SNMP::Info::CiscoPower - SNMP Interface to data stored in CISCO-POWER-ETHERNET-EXT-MIB.
AUTHOR¶
Bill Fenner
SYNOPSIS¶
# Let SNMP::Info determine the correct subclass for you. my $poe = new SNMP::Info( AutoSpecify => 1, Debug => 1, DestHost => 'myswitch', Community => 'public', Version => 2 ) or die "Can't connect to DestHost.\n"; my $class = $poe->class(); print "SNMP::Info determined this device to fall under subclass : $class\n";
DESCRIPTION¶
The Info::PowerEthernet class needs a per-device helper function to properly map the "pethPsePortTable" to "ifIndex" values. This class provides that helper, using CISCO-POWER-ETHERNET-EXT-MIB. It does not define any helpers for the extra values that this MIB contains.
Create or use a device subclass that inherit this class. Do not use directly.
For debugging purposes you can call this class directly as you would SNMP::Info
my $poe = new SNMP::Info::CiscoPower (...);
Inherited Classes¶
none.
Note that it requires that the device inherits from Info::Entity.
Required MIBs¶
GLOBALS¶
none.
TABLE METHODS¶
These are methods that return tables of information in the form of a reference to a hash.
Power Port Table¶
- $poe->peth_port_ifindex()
- Maps the "pethPsePortTable" to "ifIndex" by way of the ENTITY-MIB.
- $poe->peth_port_power()
- Power supplied by PoE ports, in milliwatts ("cpeExtPsePortPwrConsumption")
CDP Port table¶
- $poe->peth_port_neg_power()
- Power negotiated using CDP, in milliwatts ("cdpCachePowerConsumption")
2024-09-16 | perl v5.38.2 |