Scroll to navigation

SMP_REP_BROADCAST(8) SMP_UTILS SMP_REP_BROADCAST(8)

NAME

smp_rep_broadcast - invoke REPORT BROADCAST SMP function

SYNOPSIS

smp_rep_broadcast [--broadcast=BT] [--help] [--hex] [--interface=PARAMS] [--raw] [--sa=SAS_ADDR] [--verbose] [--version] SMP_DEVICE[,N]

DESCRIPTION

Sends a SAS Serial Management Protocol (SMP) REPORT BROADCAST function request to an SMP target. The SMP target is identified by the SMP_DEVICE and the --sa=SAS_ADDR. Depending on the interface, the SAS_ADDR may be deduced from the SMP_DEVICE. The mpt interface uses SMP_DEVICE to identify a HBA (an SMP initiator) and needs the additional ,N to differentiate between HBAs if there are multiple present.

OPTIONS

Mandatory arguments to long options are mandatory for short options as well.

BT is the broadcast type, an integer in the range 0 (default) to 15. Broadcast (Change) corresponds to 0. Other known broadcast types are listed in the NOTES section. BT may be decimal (default) or hexadecimal prefixed by '0x' (or '0X') or with a 'h' (or 'H') suffix.
output the usage message then exit.
output the response (less the CRC field) in hexadecimal.
interface specific parameters. In this case "interface" refers to the path through the operating system to the SMP initiator. See the smp_utils man page for more information.
send the response (less the CRC field) to stdout in binary. All error messages are sent to stderr.
specifies the SAS address of the SMP target device. The mpt interface needs this option and it will typically be an expander's SAS address. The SAS_ADDR is in decimal but most SAS addresses are shown in hexadecimal. To give a number in hexadecimal either prefix it with '0x' or put a trailing 'h' on it.
increase the verbosity of the output. Can be used multiple times.
print the version string and then exit.

NOTES

The following is a list of broadcast types:
0 Broadcast (Change)
1 Broadcast (Reserved change 0)
2 Broadcast (Reserved change 1)
3 Broadcast (SES)
4 Broadcast (Expander)
5 Broadcast (Asynchronous event)
6 Broadcast (Reserved 3)
7 Broadcast (Reserved 4)
8 Broadcast (Zone activate)

The remaining zone types (9 to 15) may be issued by the ZONED BROADCAST function.

CONFORMING TO

The SMP REPORT BROADCAST function was introduced in SAS-2 .

AUTHORS

Written by Douglas Gilbert.

REPORTING BUGS

Report bugs to <dgilbert at interlog dot com>.

COPYRIGHT

Copyright © 2011-2012 Douglas Gilbert
This software is distributed under a FreeBSD license. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.

SEE ALSO

smp_utils, smp_zoned_broadcast(smp_utils)

February 2012 smp_utils-0.98