Scroll to navigation

SNDIOD(8) System Manager's Manual SNDIOD(8)

NAME

sndiodaudio/MIDI server

SYNOPSIS

sndiod [-d] [-a flag] [-b nframes] [-C min:max] [-c min:max] [-e enc] [-F device] [-f device] [-j flag] [-L addr] [-m mode] [-Q port] [-q port] [-r rate] [-s name] [-t mode] [-U unit] [-v volume] [-w flag] [-z nframes]

DESCRIPTION

The sndiod daemon is an intermediate layer between audio or MIDI programs and the hardware. It performs the necessary audio processing to allow any program to work on any supported hardware. By default, sndiod accepts connections from programs running on the same system only; it initializes only when programs are using its services, allowing sndiod to consume a negligible amount of system resources the rest of the time. Systems with no audio hardware can use sndiod to keep hot-pluggable devices usable by default at virtually no cost.

sndiod operates as follows: it exposes at least one that any number of audio programs can connect to and use as if it was audio hardware. During playback, sndiod receives audio data concurrently from all programs, mixes it and sends the result to the hardware device. Similarly, during recording it duplicates audio data recorded from the device and sends it to all programs. Since audio data flows through the sndiod process, it has the opportunity to process audio data on the fly:

  • Change the sound encoding to overcome incompatibilities between software and hardware.
  • Route the sound from one channel to another, join stereo or split mono.
  • Control the per-application playback volume as well as the master volume.
  • Monitor the sound being played, allowing one program to record what other programs play.

Processing is configured on a per sub-device basis, meaning that the sound of all programs connected to the same sub-device will be processed according to the same configuration. Multiple sub-devices can be defined, allowing multiple configurations to coexist. The user selects the configuration a given program will use by selecting the sub-device the program uses.

sndiod exposes MIDI thru boxes (hubs), allowing programs to send MIDI messages to each other or to hardware MIDI ports in a uniform way.

Finally, sndiod exposes a control MIDI port usable for:

  • Volume control.
  • Common clock source for audio and MIDI programs.
  • Start, stop and relocate groups of audio programs.

The options are as follows:

flag
Control whether sndiod opens the audio device or the MIDI port only when needed or keeps it open all the time. If the flag is on then the audio device or MIDI port is kept open all the time, ensuring no other program can steal it. If the flag is off, then it's automatically closed, allowing other programs to have direct access to the audio device, or the device to be disconnected. The default is off.
nframes
The buffer size of the audio device in frames. A frame consists of one sample for each channel in the stream. This is the number of frames that will be buffered before being played and thus controls the playback latency. The default is 7680 or twice the block size (-z), if the block size is set.
min:max, -c min:max
The range of channel numbers for recording and playback directions, respectively any client is allowed to use. This is a subset of the audio device channels. The default is 0:1, i.e. stereo.
Enable debugging to standard error, and do not disassociate from the controlling terminal. Can be specified multiple times to further increase log verbosity.
enc
Attempt to configure the device to use this encoding. The default is s16. Encoding names use the following scheme: signedness (s or u) followed by the precision in bits, the byte-order (le or be), the number of bytes per sample, and the alignment (msb or lsb). Only the signedness and the precision are mandatory. Examples: u8, s16le, s24le3, s24le4lsb.
device
Same as -f except that if the device is disconnected, the one given with the previous -f or -F option will be used.
device
Add this sndio(7) audio device to devices used for playing and/or recording. Preceding per-device options (-aberwz) apply to this device. Sub-devices (-s) that are applied after will be attached to this device. Device mode and parameters are determined from sub-devices attached to it. If no -f option is used, sndiod will use rsnd/0, rsnd/1, ..., rsnd/3.
flag
Control whether program channels are joined or expanded if the number of channels requested by a program is not equal to the device number of channels. If the flag is off then client channels are routed to the corresponding device channel, possibly discarding channels not present in the device. If the flag is on, then a single client channel may be sent on multiple device channels, or multiple client channels may be sent to a single device channel. For instance, this feature could be used for mono to stereo conversions. The default is on.
addr
Specify a local network address sndiod should listen on; sndiod will listen on TCP port 11025+n, where n is the unit number specified with -U. Without this option, sndiod listens on the UNIX-domain socket only, and is not reachable from any network. If the option argument is ‘-’ then sndiod will accept connections from any address. As the communication is not secure, this option is only suitable for local networks where all hosts and users are trusted.
mode
Set the sub-device mode. Valid modes are play, rec, and mon, corresponding to playback, recording and monitoring. A monitoring stream is a fake recording stream corresponding to the mix of all playback streams. Multiple modes can be specified, separated by commas, but the same sub-device cannot be used for both recording and monitoring. The default is play,rec (i.e. full-duplex).
port
Specify an alternate MIDI port to use. If it doesn't work, the one given with the last -Q or -q options will be used. For instance, this allows a USB MIDI controller to be replaced without the need to restart programs using it.
port
Expose the given MIDI port. This allows multiple programs to share the port. If no -q option is used, sndiod will use rmidi/0, rmidi/1, ..., rmidi/7.
rate
Attempt to force the device to use this sample rate in Hertz. The default is 48000.
name
Add name to the list of sub-devices to expose. This allows clients to use sndiod instead of the physical audio device for audio input and output in order to share the physical device with other clients. Defining multiple sub-devices allows splitting a physical audio device into sub-devices having different properties (e.g. channel ranges). The given name corresponds to the “option” part of the sndio(7) device name string.
mode
Select the way clients are controlled by MIDI Machine Control (MMC) messages received by sndiod. If the mode is off (the default), then programs are not affected by MMC messages. If the mode is slave, then programs are started synchronously by MMC start messages; additionally, the server clock is exposed as MIDI Time Code (MTC) messages allowing MTC-capable software or hardware to be synchronized to audio programs.
unit
Unit number. Each sndiod server instance has a unique unit number, used in sndio(7) device names. The default is 0.
volume
Software volume attenuation of playback. The value must be between 1 and 127, corresponding to -42dB and -0dB attenuation in 1/3dB steps. Clients inherit this parameter. Reducing the volume in advance allows a client's volume to stay independent from the number of clients as long as their number is small enough. 18 volume units (i.e. -6dB attenuation) allows the number of playback programs to be doubled. The default is 127.
flag
Control sndiod behaviour when the maximum volume of the hardware is reached and a new program starts playing. This happens only when volumes are not properly set using the -v option. If the flag is on, then the master volume is automatically adjusted to avoid clipping. The default is off.
nframes
The audio device block size in frames. This is the number of frames between audio clock ticks, i.e. the clock resolution. If a sub-device is created with the -t option, and MTC is used for synchronization, the clock resolution must be 96, 100 or 120 ticks per second for maximum accuracy. For instance, 100 ticks per second at 48000Hz corresponds to a 480 frame block size. The default is 480 or half of the buffer size (-b), if the buffer size is set.

On the command line, per-device parameters (-aberwz) must precede the device definition (-f), and per-sub-device parameters (-Ccjmtvx) must precede the sub-device definition (-s). Sub-device definitions (-s) must follow the definition of the device (-f) to which they are attached.

If no audio devices (-f) are specified, settings are applied as if the default device is specified. If no sub-devices (-s) are specified for a device, a default sub-device is created attached to it. If a device (-f) is defined twice, both definitions are merged: parameters of the first one are used but sub-devices (-s) of both definitions are created. The default sndio(7) device used by sndiod is rsnd/0, and the default sub-device exposed by sndiod is snd/default.

If sndiod is sent SIGINT or SIGTERM, it terminates. If sndiod is sent SIGHUP, it reopens all audio devices and MIDI ports.

By default, when the program cannot accept recorded data fast enough or cannot provide data to play fast enough, the program is paused, i.e. samples that cannot be written are discarded and samples that cannot be read are replaced by silence. If a sub-device is created with the -t option, then recorded samples are discarded, but the same amount of silence will be written once the program is unblocked, in order to reach the right position in time. Similarly silence is played, but the same amount of samples will be discarded once the program is unblocked. This ensures proper synchronization between programs.

MIDI CONTROL

sndiod creates a MIDI port with the same name as the exposed audio sub-device to which MIDI programs can connect. sndiod exposes the audio device clock and allows audio device properties to be controlled through MIDI.

A MIDI channel is assigned to each stream, and the volume is changed using the standard volume controller (number 7). Similarly, when the audio client changes its volume, the same MIDI controller message is sent out; it can be used for instance for monitoring or as feedback for motorized faders.

The master volume can be changed using the standard master volume system exclusive message.

Streams created with the -t option are controlled by the following MMC messages:

relocate
This message is ignored by audio sndiod clients, but the given time position is sent to MIDI ports as an MTC “full frame” message forcing all MTC-slaves to relocate to the given position (see below).
start
Put all streams in starting mode. In this mode, sndiod waits for all streams to become ready to start, and then starts them synchronously. Once started, new streams can be created (sndiod) but they will be blocked until the next stop-to-start transition.
stop
Put all streams in stopped mode (the default). In this mode, any stream attempting to start playback or recording is paused. Client streams that are already started are not affected until they stop and try to start again.

Streams created with the -t option export the sndiod device clock using MTC, allowing non-audio software or hardware to be synchronized to the audio stream. Maximum accuracy is achieved when the number of blocks per second is equal to one of the standard MTC clock rates (96, 100 and 120Hz). The following sample rates (-r) and block sizes (-z) are recommended:

  • 44100Hz, 441 frames (MTC rate is 100Hz)
  • 48000Hz, 400 frames (MTC rate is 120Hz)
  • 48000Hz, 480 frames (MTC rate is 100Hz)
  • 48000Hz, 500 frames (MTC rate is 96Hz)

For instance, the following command will create two devices: the default snd/default and a MIDI-controlled snd/mmc:

$ sndiod -r 48000 -z 400 -s default -t slave -s mmc

Streams connected to snd/default behave normally, while streams connected to snd/mmc wait for the MMC start signal and start synchronously. Regardless of which device a stream is connected to, its playback volume knob is exposed.

HOT PLUGGING

If devices specified with -F are unavailable when needed or unplugged at runtime, sndiod will attempt to seamlessly fall back to the last device specified.

sndiod will not automatically switch to specified device that is plugged at runtime. Instead, sndioctl(1) must be used to change the server.device control.

For instance, specifying a USB device with -F following a PCI device with -f allows sndiod to use the USB one preferably when it's connected and to fall back to the PCI one when it's disconnected.

EXAMPLES

Start server using default parameters, creating an additional sub-device for output to channels 2:3 only (rear speakers on most cards), exposing the snd/default and snd/rear devices:

$ sndiod -s default -c 2:3 -s rear

Start server creating the default sub-device with low volume and an additional sub-device for high volume output, exposing the snd/default and snd/max devices:

$ sndiod -v 65 -s default -v 127 -s max

Start server configuring the audio device to use a 48kHz sample frequency, 240-frame block size, and 2-block buffers. The corresponding latency is 10ms, which is the time it takes the sound to propagate 3.5 meters.

$ sndiod -r 48000 -b 480 -z 240

SEE ALSO

sndio(7)

BUGS

Resampling is low quality; down-sampling especially should be avoided when recording.

If -a off is used, sndiod creates sub-devices to expose first and then opens the audio hardware on demand. Technically, this allows sndiod to attempt to use one of the sub-devices it exposes as an audio device, creating a deadlock. There's nothing to prevent the user from shooting themselves in the foot by creating such a deadlock.

October 21, 2024 Debian