NAME¶
modbus_new_tcp - create a libmodbus context for TCP/IPv4SYNOPSIS¶
modbus_t *modbus_new_tcp(const char *ip, int port);DESCRIPTION¶
The modbus_new_tcp() function shall allocate and initialize a modbus_t structure to communicate with a Modbus TCP/IPv4 server.RETURN VALUE¶
The modbus_new_tcp() function shall return a pointer to a modbus_t structure if successful. Otherwise it shall return NULL and set errno to one of the values defined below.ERRORS¶
EINVALAn invalid IP address was given.
EXAMPLE¶
modbus_t *ctx;
ctx = modbus_new_tcp("127.0.0.1", 1502);
if (ctx == NULL) {
fprintf(stderr, "Unable to allocate libmodbus context\n");
return -1;
}
if (modbus_connect(ctx) == -1) {
fprintf(stderr, "Connection failed: %s\n", modbus_strerror(errno));
modbus_free(ctx);
return -1;
}
SEE ALSO¶
modbus_new_rtu(3) modbus_free(3)AUTHORS¶