NAME¶
Ifeffit::Demeter::FluorescenceEXAFS - Corrections for fluorescence EXAFS data
DESCRIPTION¶
This provides class methods for computing corrections to fluorescence EXAFS data
  due to normalization, I0, and self-absorption effects. The corrections are
  computed from x-ray absorption coefficients provided by the Xray::Absorption
  package.
METHODS¶
Note that the values returned for all methods depend on the data resource used.
  See Xray::Absorption.
  - "mcmaster"
 
  - This is called "mcmaster" for historical reasons.
      It calculates the normalization correcion for a given element.
    
 
      $sigma_mm = Xray::FluorescenceEXAFS->mcmaster($element, $edge);
    
     
    It takes the central atoms tag and the alphanumeric edge symbol as arguments
      and returns the normalization correction in units of Angstrom squared.
     
    "normalization" and "edgestep" are aliases for this
      method. 
  - "i0"
 
  - This calculates the correcion due to the I0 fill gases in a
      fluorescence experiment.
    
 
      $gases = {nitrogen=>$nitrogen, argon=>$argon, krypton=>$krypton};
  $sigma_i0 = Xray::FluorescenceEXAFS->i_zero($central, $edge, $gases);
    
     
    It takes the central atoms tag, the alphanumeric edge symbol, and a
      reference to a hash containing the volume percentages of the three gases
      as arguments. It assumes that any remaining volume is filled with helium
      and it correctly accounts for the fact that nitrogen is a diatom. It
      returns the I0 correction in units of Angstrom squared.
     
    "i_zero" and "izero" are aliases for this method. 
  - "self"
 
  - This calculates the correcion due to self-absorption
      fluorescence experiment. It assumes that the sample is infinately thick
      and that the entry and exit angles of the photons are the same.
    
 
      $contents = {Y=>1, Ba=>2, Cu=>3, O=>7};
  ($amp_i0, $sigma_i0) = Xray::FluorescenceEXAFS->self($central, $edge, $contents);
    
     
    It takes the central atoms tag, the alphanumeric edge symbol, and a
      reference to a hash which counts the atoms in the unit cell. It returns a
      list whose zeroth element is the multiplicative amplitude correction and
      whose first element is the sigma^2 correction in units of Angstrom
      squared.
     
    "overabsorption" is an aliases for this method. 
BUGS AND LIMITATIONS¶
  - •
 
  - Fourth cumulant corrections are not calculated.
 
  - •
 
  - Geometry and thickness effects are not included in the self
      absorption calculation
 
Please report problems to Bruce Ravel (bravel AT bnl DOT gov)
Patches are welcome.
AUTHOR¶
Bruce Ravel (bravel AT bnl DOT gov)
http://cars9.uchicago.edu/~ravel/software/
LICENCE AND COPYRIGHT¶
Copyright (c) 2006-2008 Bruce Ravel (bravel AT bnl DOT gov). All rights
  reserved.
This module is free software; you can redistribute it and/or modify it under the
  same terms as Perl itself. See perlartistic.
This program is distributed in the hope that it will be useful, but WITHOUT ANY
  WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR
  A PARTICULAR PURPOSE.