NAME¶
ocf_pacemaker_HealthCPU - System health CPU usageSYNOPSIS¶
OCF_RESKEY_state=string OCF_RESKEY_yellow_limit=string OCF_RESKEY_red_limit=stringDESCRIPTION¶
Systhem health agent that measures the CPU ideling and updates the #health-cpu attribute.SUPPORTED PARAMETERS¶
OCF_RESKEY_state = string [/health-cpu-{OCF_RESOURCE_INSTANCE}.state]State file
Location to store the resource state in.
OCF_RESKEY_yellow_limit = string [50]
Lower limit for yellow health attribute
Lower (!) limit of idle percentage to switch the health attribute to yellow.
I.e. the #health-cpu will go yellow if the %idle of the CPU falls below
50%.
OCF_RESKEY_red_limit = string [10]
Lower limit for red health attribute
Lower (!) limit of idle percentage to switch the health attribute to red. I.e.
the #health-cpu will go red if the %idle of the CPU falls below 10%.
AUTHOR¶
Andrew Beekhof <andrew@beekhof.net>Author.