Scroll to navigation

READ(1) User Commands READ(1)

NAME

Read - Read Target Test Chart.

DESCRIPTION

Read Target Test Chart, Version 1.3.5 Author: Graeme W. Gill, licensed under the AGPL Version 3 usage: chartread [-options] outfile
-v
Verbose mode
-c listno
Set communication port from the following list (default 1)
1 = '/dev/ttyS0' 2 = '/dev/ttyS1' 3 = '/dev/ttyS2' 4 = '/dev/ttyS3'
-t
Use transmission measurement mode
-d
Use display measurement mode (white Y relative results)
-y c|l
Display type (if emissive), c = CRT, l = LCD
-e
Emissive for transparency on a light box
-p
Measure patch by patch rather than strip
-x [lx]
Take external values, either L*a*b* (-xl) or XYZ (-xx).
-n
Don't save spectral information (default saves spectral)
-l
Save CIE as D50 L*a*b* rather than XYZ
-L
Save CIE as D50 L*a*b* as well as XYZ
-r
Resume reading partly read chart
-I file.cal
Override calibration info from .ti2 in resulting .ti3
-F filter
Set filter configuration (if aplicable):
n
None
p
Polarising filter
6
D65
u
U.V. Cut
-N
Disable auto calibration of instrument
-B
Disable auto bi-directional strip recognition
-H
Use high resolution spectrum mode (if available)
-T ratio
Modify strip patch consistency tolerance by ratio
-S
Suppress wrong strip & unexpected value warnings
-W n|h|x
Override serial port flow control: n = none, h = HW, x = Xon/Xoff
-D [level]
Print debug diagnostics to stderr
outfile
Base name for input[ti2]/output[ti3] file
Author: Graeme W. Gill, licensed under the AGPL Version 3 usage: chartread [-options] outfile
-v
Verbose mode
-c listno
Set communication port from the following list (default 1)
1 = '/dev/ttyS0' 2 = '/dev/ttyS1' 3 = '/dev/ttyS2' 4 = '/dev/ttyS3'
-t
Use transmission measurement mode
-d
Use display measurement mode (white Y relative results)
-y c|l
Display type (if emissive), c = CRT, l = LCD
-e
Emissive for transparency on a light box
-p
Measure patch by patch rather than strip
-x [lx]
Take external values, either L*a*b* (-xl) or XYZ (-xx).
-n
Don't save spectral information (default saves spectral)
-l
Save CIE as D50 L*a*b* rather than XYZ
-L
Save CIE as D50 L*a*b* as well as XYZ
-r
Resume reading partly read chart
-I file.cal
Override calibration info from .ti2 in resulting .ti3
-F filter
Set filter configuration (if aplicable):
n
None
p
Polarising filter
6
D65
u
U.V. Cut
-N
Disable auto calibration of instrument
-B
Disable auto bi-directional strip recognition
-H
Use high resolution spectrum mode (if available)
-T ratio
Modify strip patch consistency tolerance by ratio
-S
Suppress wrong strip & unexpected value warnings
-W n|h|x
Override serial port flow control: n = none, h = HW, x = Xon/Xoff
-D [level]
Print debug diagnostics to stderr
outfile
Base name for input[ti2]/output[ti3] file
November 2011 Read Target Test Chart, Version 1.3.5