NAME¶
Read - Read Target Test Chart.
DESCRIPTION¶
Read Target Test Chart, Version 1.3.5 Author: Graeme W. Gill, licensed under the
AGPL Version 3 usage: chartread [-options] outfile
- -v
- Verbose mode
- -c listno
- Set communication port from the following list (default
1)
- 1 = '/dev/ttyS0' 2 = '/dev/ttyS1' 3 = '/dev/ttyS2' 4 =
'/dev/ttyS3'
- -t
- Use transmission measurement mode
- -d
- Use display measurement mode (white Y relative
results)
- -y c|l
- Display type (if emissive), c = CRT, l = LCD
- -e
- Emissive for transparency on a light box
- -p
- Measure patch by patch rather than strip
- -x [lx]
- Take external values, either L*a*b* (-xl) or XYZ
(-xx).
- -n
- Don't save spectral information (default saves
spectral)
- -l
- Save CIE as D50 L*a*b* rather than XYZ
- -L
- Save CIE as D50 L*a*b* as well as XYZ
- -r
- Resume reading partly read chart
- -I file.cal
- Override calibration info from .ti2 in resulting .ti3
- -F filter
- Set filter configuration (if aplicable):
- n
- None
- p
- Polarising filter
- 6
- D65
- u
- U.V. Cut
- -N
- Disable auto calibration of instrument
- -B
- Disable auto bi-directional strip recognition
- -H
- Use high resolution spectrum mode (if available)
- -T ratio
- Modify strip patch consistency tolerance by ratio
- -S
- Suppress wrong strip & unexpected value warnings
- -W n|h|x
- Override serial port flow control: n = none, h = HW, x =
Xon/Xoff
- -D [level]
- Print debug diagnostics to stderr
- outfile
- Base name for input[ti2]/output[ti3] file
Author: Graeme W. Gill, licensed under the AGPL Version 3 usage: chartread
[-options] outfile
- -v
- Verbose mode
- -c listno
- Set communication port from the following list (default
1)
- 1 = '/dev/ttyS0' 2 = '/dev/ttyS1' 3 = '/dev/ttyS2' 4 =
'/dev/ttyS3'
- -t
- Use transmission measurement mode
- -d
- Use display measurement mode (white Y relative
results)
- -y c|l
- Display type (if emissive), c = CRT, l = LCD
- -e
- Emissive for transparency on a light box
- -p
- Measure patch by patch rather than strip
- -x [lx]
- Take external values, either L*a*b* (-xl) or XYZ
(-xx).
- -n
- Don't save spectral information (default saves
spectral)
- -l
- Save CIE as D50 L*a*b* rather than XYZ
- -L
- Save CIE as D50 L*a*b* as well as XYZ
- -r
- Resume reading partly read chart
- -I file.cal
- Override calibration info from .ti2 in resulting .ti3
- -F filter
- Set filter configuration (if aplicable):
- n
- None
- p
- Polarising filter
- 6
- D65
- u
- U.V. Cut
- -N
- Disable auto calibration of instrument
- -B
- Disable auto bi-directional strip recognition
- -H
- Use high resolution spectrum mode (if available)
- -T ratio
- Modify strip patch consistency tolerance by ratio
- -S
- Suppress wrong strip & unexpected value warnings
- -W n|h|x
- Override serial port flow control: n = none, h = HW, x =
Xon/Xoff
- -D [level]
- Print debug diagnostics to stderr
- outfile
- Base name for input[ti2]/output[ti3] file